Send Message
Home ProductsNon Destructive Testing Equipment

0-1500μm Non Destructive Testing Equipment Fe and NFe Coating Thickness Tester

Certification
China Dongguan Quality Control Technology Co., Ltd. certification
China Dongguan Quality Control Technology Co., Ltd. certification
Customer Reviews
The touch screen micro vickers hardness tester has been installed a few weeks ago, everything is OK. Thanks for your advice and excellent service.

—— Mr. David Chambers

Thanks for the fast delivery and our customer is very satisfied for the rockwell hardness tester, and hope more orders soon.

—— Neil Renato

After we visited the customer, they finally decided to purchase Brinell hardness tester iBrin-413Z, now we have installed the unit at customer’s site,

—— Fermin Lee

Thank you for the indenters (diamond  cone 120 degrees). We recently got it and already tested it. Indenters  are good as we expected. 

—— Dalius Skinulis

The Measurements are good for Brinell Tester HBST-3000.

—— Sun Chull Kim

Hey, the hardness tester iVick-484ST was installed last week and works well, thanks for the professional support.

—— Sabinian Smith

I am glad to inform you that the installation of the SHB-3000C Brinell hardness tester has been finished successfully. I would like to thank you!

—— Robbin

I'm Online Chat Now

0-1500μm Non Destructive Testing Equipment Fe and NFe Coating Thickness Tester

0-1500μm Non Destructive Testing Equipment Fe and NFe Coating Thickness Tester
0-1500μm Non Destructive Testing Equipment Fe and NFe Coating Thickness Tester 0-1500μm Non Destructive Testing Equipment Fe and NFe Coating Thickness Tester 0-1500μm Non Destructive Testing Equipment Fe and NFe Coating Thickness Tester 0-1500μm Non Destructive Testing Equipment Fe and NFe Coating Thickness Tester

Large Image :  0-1500μm Non Destructive Testing Equipment Fe and NFe Coating Thickness Tester

Product Details:
Place of Origin: Dongguan/China
Brand Name: iqualitrol
Certification: CE
Model Number: iThick-10FN
Payment & Shipping Terms:
Minimum Order Quantity: 1 Set
Price: Negotiable
Packaging Details: Carton Box
Delivery Time: 5 Working Days
Payment Terms: T/T
Supply Ability: 50 Sets per Month
Detailed Product Description
Model: IThick-10FN Name: Non Destructive Testing Machine
Principle: Magnetic, Eddy Current Measuring: Range 0-1500μm
Tolerance: ± (2%H+2) (μm) Display: LED Backlight
Magnetic Method (Fe): Non-magnetic Coatings On Steel, Iron Eddy Current Method (NFe): Non-conductive Coatings On Copper, Aluminum
High Light:

iqualitrol Non Destructive Testing Equipment

,

1500μm Non Destructive Testing Equipment

,

Fe and NFe Coating Thickness Tester

 
Fe and NFe Coating Thickness Tester Measuring Range 0-1500μm Non Destructive Testing Machine
 
Brief Introduction: 
The non-destructive coating thickness measurements can be taken on either magnetic steel surfaces or non-magnetic metal surfaces such as stainless steel or aluminium. Digital coating thickness gauges are ideal to measure coating thickness on metallic substrates. Electromagnetic induction is used for non-magnetic coatings on ferrous substrates such as steel, whilst the eddy current principle is used for non-conductive coatings on non-ferrous metal substrates.
 
Magnetic Method (Fe): Measuring the thickness of non-magnetic coatings on steel, iron and other ferromagnetic metal substrates, e.g. painting, varieties of anti-corrosion coating, powder spraying, plastic, rubber, synthetic material, phosphate coating, chromium, zinc, Aluminum, tin and cadmium, etc.
 
Eddy Current Method (NFe): measuring the thickness of non-conductive coatings on copper, aluminum, stainless steel and other non-ferromagnetic substrates, e.g. painting, varieties of anti-corrosion coating, powder spraying, plastic, rubber, synthetic material, oxide film and phosphate film, etc.


 
0-1500μm Non Destructive Testing Equipment Fe and NFe Coating Thickness Tester 00-1500μm Non Destructive Testing Equipment Fe and NFe Coating Thickness Tester 1
 
0-1500μm Non Destructive Testing Equipment Fe and NFe Coating Thickness Tester 2
 

 
Technical Specifications:

 

DisplayHigh Contrast Segment Liquid Crystal Display (LED Backlight)
StatisticsN, MAX, MIN, MEAN and STD.DEV
CalibrationZero, One-Point and Two-Point Calibration
Working Temperature-10℃~+50℃
Auto Power-offAuto off after 3 minutes of inactivity
Power2AA size batteries, low-voltage indication function
Weight200g including batteries
Size149mm×73mm×32mm (H×W×D)

 
 
Standard Delivery:
Main Unit -- 1 pc
Calibration Foils-- 1 set
Zero Plate(Fe/Al)--1 pc
DataView Software--1pc
User Manual, Packing List, Warranty Card -- 1 pc
Instrument Case--1pc
**Note: Without Battery if By Air Transportation.**
 

0-1500μm Non Destructive Testing Equipment Fe and NFe Coating Thickness Tester 3
 

ModeliThick-10FiThick-10NiThick-10FNiThick-10FH
Measuring PrincipleMagneticEddy CurrentMagnetic/Eddy CurrentMagnetic
Measuring Range0-3000μm0-2000μm0-1500μm0-10000μm
Low Range Sensitivity0.10.10.11
Tolerance(μm)±(2%H+2)±(2%H+2)±(2%H+2)±(2%H+10)
Min. Curvature Radius55510
Min. Measuring Surface20202040
Min. Substrate Thickness0.50.50.52

 
0-1500μm Non Destructive Testing Equipment Fe and NFe Coating Thickness Tester 4
 
 
Why you need to Calibrate a Coating Thickness Gauge before testing?
 
Calibration of coating thickness gauges will be affected by the type of material, the shape and the surface finish of the metal substrate to be tested.
 
For example the magnetic properties of steel alloys vary and the conductivity of different aluminium alloys and different non-ferrous metals, copper, brass, stainless steel etc. also vary. These variations can affect the linearity of a coating thickness gauge. This means that a gauge set-up on mild steel for example will read a different value for the same thickness coating on high carbon steel. Similar linearity effects are seen on thin or curved substrates and particularly on profiled substrates such as blast cleaned steel used for structural steelworks.
 
To overcome these effects most coating thickness gauges have features that allow you to set the gauge to the work being carried out, thus maximising the accuracy of the readings.
 
 
Adjusting a Coating Thickness Gauge
 
Adjustment is the technique whereby you can set-up the coating thickness gauge for the conditions prevailing for the work in hand. In addition to material differences, shape and surface finish the adjustment may be carried out at an elevated temperature or in the presence of a stray magnetic field. By adjusting the coating thickness gauge to these prevailing conditions the resulting errors are greatly reduced and even eliminated.
 
The effect of surface roughness, particularly that produced by deliberately profiling the substrate by blast cleaning with either grit or shot or by mechanical cleaning, is quite significant.
 

Contact Details
Dongguan Quality Control Technology Co., Ltd.

Contact Person: Mr. Raymond Chung

Tel: 86-13711988687

Fax: 86-769-22784276

Send your inquiry directly to us (0 / 3000)