Send Message
Home ProductsVickers Hardness Testing Machine

Vertical Space 170mm Hardness Check Machine 0.25μm 0.125μm With Automatic Turret

Certification
China Dongguan Quality Control Technology Co., Ltd. certification
China Dongguan Quality Control Technology Co., Ltd. certification
Customer Reviews
The touch screen micro vickers hardness tester has been installed a few weeks ago, everything is OK. Thanks for your advice and excellent service.

—— Mr. David Chambers

Thanks for the fast delivery and our customer is very satisfied for the rockwell hardness tester, and hope more orders soon.

—— Neil Renato

After we visited the customer, they finally decided to purchase Brinell hardness tester iBrin-413Z, now we have installed the unit at customer’s site,

—— Fermin Lee

Thank you for the indenters (diamond  cone 120 degrees). We recently got it and already tested it. Indenters  are good as we expected. 

—— Dalius Skinulis

The Measurements are good for Brinell Tester HBST-3000.

—— Sun Chull Kim

Hey, the hardness tester iVick-484ST was installed last week and works well, thanks for the professional support.

—— Sabinian Smith

I am glad to inform you that the installation of the SHB-3000C Brinell hardness tester has been finished successfully. I would like to thank you!

—— Robbin

I'm Online Chat Now

Vertical Space 170mm Hardness Check Machine 0.25μm 0.125μm With Automatic Turret

Vertical Space 170mm Hardness Check Machine 0.25μm 0.125μm With Automatic Turret
Vertical Space 170mm Hardness Check Machine 0.25μm 0.125μm With Automatic Turret Vertical Space 170mm Hardness Check Machine 0.25μm 0.125μm With Automatic Turret Vertical Space 170mm Hardness Check Machine 0.25μm 0.125μm With Automatic Turret Vertical Space 170mm Hardness Check Machine 0.25μm 0.125μm With Automatic Turret Vertical Space 170mm Hardness Check Machine 0.25μm 0.125μm With Automatic Turret

Large Image :  Vertical Space 170mm Hardness Check Machine 0.25μm 0.125μm With Automatic Turret

Product Details:
Place of Origin: Dongguan/China
Brand Name: iqualitrol
Certification: CE
Model Number: iVick-477HP
Payment & Shipping Terms:
Minimum Order Quantity: 1 Set
Price: Negotiable
Packaging Details: Plywood Box
Delivery Time: 20 Working Days
Payment Terms: T/T, Western Union
Supply Ability: 30 Sets per Month
Detailed Product Description
Turret: Automatic Turret Data Output: Built-in Mini Printer And RS232
Height: Max Specimen Height 170mm Throat: Max Horizontal Space 130mm
Objective: 10x, 20x Dwell Time: 0 - 60 Seconds, Adjustable
High Light:

170mm Hardness Check Machine

,

Hardness Check Machine 0.25μm

 

Vertical Space 170mm 10X Eyepiece Digital Vickers Hardness Tester with Automatic Turret

 

Technical Data Download: iqualitrol Vickers Hardness Tester iVick-477HP

 

Product Summary:

iqualitrol iVick-477HP Digital Vickers hardness tester adopts load cell control system, improves the precision of the test force and the repeatability and stability of the indicating value.
 
With digital measuring eyepiece, no need for checking the table or inputting the diagonal of the indentation, it can directly show the test force, indentation length, dwell time, test numbers, conversion scale, date and time.
 
As long as press the eyepiece button after measuring the indentation length, it can automatically get the hardness value and shows on the screen. 
Available to install optional LCD video measuring device and CCD image automatic measuring system.
 
Application range:
Suitable for ferrous metal, non-ferrous metals, IC thin sections, coatings, ply-metals; glass, ceramics, agate, precious stones, thin plastic sections etc.; hardness testing such as that on the depth and the trapezium of the carbonized layers and quench hardened layers.
 
Technical Specification:

Model iVick-477HP
Test Force kgf 0.5kgf, 1kgf, 2kgf, 2.5kgf, 3kgf, 5kgf, 10kgf, 20kgf, 30kgf
N 4.90N, 9.80N, 19.6N, 24.5N, 29.4N, 49N, 98N, 196N, 294N
Test Range 1HV~2967HV
Loading Method Automatic (Loading/Dwell/Unloading)
Turret Manual Turret
Data Output Built-in Mini Printer and RS232 Interface
Objective 10x, 20x
Eyepiece 10x
Total Magnification 100x, 200x
Resolution 0.25μm, 0.125μm
Dwell Time 0~60s
Light Source Halogen Lamp
Max. Height of Specimen 170mm
Throat 130mm
Power Supply AC220V/50Hz/1Ph, AC110V/60Hz/1Ph
Execute Standard ISO 6507, ASTM E92, JIS Z2244, GB/T 4340.2
Dimension 530×280×630mm, Packing Dimension:620×450×740mm
Weight Net Weight: 35kg, Gross Weight: 47kg

 
Packing List:

Name Qty Name Qty
Instrument Main Body 1 set 10×Digital Measuring Eyepiece 1 pc
Diamond Vickers Indenter 1 pc 10x, 20x Objective each 1 pc
Plane Test Table 1 pc V-shaped Test Table 1 pc
Power Cable 1 pc Level 1 pc
Horizontal Regulating Screw 4 pcs Halogen Lamp12V/15~20W 1 pc
Fuse1A 2 pcs Screw Driver 1 pc
Inner Hexagon Spanner 2.5mm 1 pc Hardness Block 400~500 HV5 1 pc
Hardness Block 700~800 HV30 1 pc Anti-dust Cover 1 pc
Usage Instruction Manual 1 copy    

 

iqualitrol Vickers Hardness Tester at Customer's Quality Control Lab:

Vertical Space 170mm Hardness Check Machine 0.25μm 0.125μm With Automatic Turret 0

 

Vertical Space 170mm Hardness Check Machine 0.25μm 0.125μm With Automatic Turret 1

 

The Vickers hardness test method consists of indenting the test material with a diamond indenter, in the form of a right pyramid with a square base and an angle of 136 degrees between opposite faces subjected to a load of 1 to 100 kgf. The full load is normally applied for 10 to 15 seconds.

 

The two diagonals of the indentation left in the surface of the material after removal of the load are measured using a microscope and their average calculated. The area of the sloping surface of the indentation is calculated. The Vickers hardness is the quotient obtained by dividing the kgf load by the square mm area of indentation.

 

When the mean diagonal of the indentation has been determined the Vickers hardness may be calculated from the formula, but is more convenient to use conversion tables.

Vertical Space 170mm Hardness Check Machine 0.25μm 0.125μm With Automatic Turret 2

 

The Vickers hardness should be reported like 800 HV/10, which means a Vickers hardness of 800, was obtained using a 10kgf force. Several different loading settings give practically identical hardness numbers on uniform material, which is much better than the arbitrary changing of scale with the other hardness testing methods.

 

The advantages of the Vickers hardness test are that extremely accurate readings can be taken, and just one type of indenter is used for all types of metals and surface treatments. Although thoroughly adaptable and very precise for testing the softest and hardest of materials, under varying loads, the Vickers machine is a floor standing unit that is more expensive than the Brinell or Rockwell machines.

 

Contact Details
Dongguan Quality Control Technology Co., Ltd.

Contact Person: Mr. Raymond Chung

Tel: 86-13711988687

Fax: 86-769-22784276

Send your inquiry directly to us (0 / 3000)